Multi Gas Analyzer
Agasthya 2013 Series
BI 7000

The Agasthya 2013 Series Gas Analyzer BI 7000 is designed to meet the needs of various industrial process with combination of technologies. The technology employed is tried and tested to ensure the user experiences maximum reliability and accuracy.

Up to six gases can be analyzed simultaneously with scalable ranges for each gas. BI 7000 is an ideal solution to protect initial investment & long lasting performances.

Agsthya 2013 Series BI 7000
  • 32-Bit Cortex-M3 ARM Processor
  • 5.7″ Colour TFT Display
  • Tried and tested technology with proven reliability
  • Built-in to simultaneously analyze up to 6 gases
  • Scalable ranges available for each gas
  • Wide range of gas selectivity
  • Compensated for temperature and pressure of media
  • Isolated 4-20 mA analog output for each gas
  • RS 485, MODBUS protocol
  • Parameter
  • Oxygen
  • Resolution
  • 0.1%
  • Scalable Range
  • 0–1%, 0–25%, 0–100%
  • Sensor Technology
  • Paramagnetic
  • Gas Sensing Method
  • Through Flow
  • Accuracy & Linearity
  • ≤ ±2% O₂
  • Repeatability
  • ≤ ±0.01% O₂
  • Drift
  • ≤ ±0.2% O₂ per month
  • Response Time (T90)
  • ≤ 3 seconds
  • Operating Temperature
  • 4°C to 65°C
  • Analog Output
  • 4–20 mA (max load resistance up to 500 Ω)
  • Digital Interface
  • RS485 with MODBUS Protocol
  • Relay Output
  • 2 Nos. potential free contacts for alarms
  • Power Supply
  • 110/230 VAC, 50 Hz
  • Humidity
  • 5–95% RH
  • Flow Meter
  • 0.1–1 LPM
  • Sample Connection
  • 1/4 inch S.S. Connection
  • Area Classification
  • General Purpose, Ex-proof on request (ATEX Zone 1, Gas Group IIA/IIB, T4)
  • Cable Entries
  • 2 Nos., 1/2″ NPT (F)
  • Ingress Protection
  • IP65 or better
  • Standard
  • IEC/EN 61010-1:2010
  • Sample Conditioning Unit
    • Pre and post cooler fine filters to remove drain, dust and mist in sample gas
    • Auto drain and auto purging (blow back) facilities
    • 2-way solenoid valves for switching, sampling, purging, draining and calibration
    • Flowmeter to regulate and monitor sample gas
    • Drain pump for continuous removal of condensate
  • Cabinet
    • Industrial cabinet
    • Meets IP54 standard (others on request)
    • Inbuilt air conditioning system
    • Automatic cabinet illumination on door open
    • Earthing bar assembly
    • 180° door opening
    • Safe Area Cabinet Dimensions: 1500 (H) × 800 (W) × 800 (D) mm
    • Purge Panel for Area classification: Zone 1 & Zone 2, Gas Group IIA, IIB, IIC, T4
    • Purge Panel Dimensions: 1900 (H) × 1200 (W) × 800 (D)
  • Aluminium
  • Cement
  • Distillery
  • Chlor Alkali
  • Fertilizers
  • Iron & steel
  • Oil refinery
  • Petrochemical
  • Pharmaceuticals
  • Power Plants
  • Research Institute
  • University
  • Thermal Power Plants
  • Pulp & paper
  • Sugar
  • Zinc
  • Copper
  • Boiler
  • Biomedical waste Incinerator
  • Common Hazardous Waste Incinerator