Call Now : +91 869 305 0520

NEW Visit us at stall..257… At Boiler India Exhibition, Navi Mumbai

x

Agasthya 2013 Series Portable Ambient Air Quality Monitoring Analyzer BI 9100

Agasthya 2013 Series Portable Ambient Air Quality Monitoring Analyzer BI 9100

The Agasthya 2013 Series Portable Ambient Air Quality Monitoring Analyzer BI 9100 delivers accurate intermittent measurement data in real time for a wide range of air quality criteria in a compact and modular package. Measurable parameters include Ozone (O3), Nitrogen Dioxide (NO2), Nitric Oxide (NO), Carbon Monoxide (CO), Carbon Dioxide (CO2), Sulphur Dioxide (SO2), Hydrogen Sulphide (H2S) and other toxic gases.

Electrochemical and IR Sensor technology deliver high performance within a flexible platform.

The modular design of BI 9100 AQMS also facilitates cost-effective service. Data is stored in memory and remotely accessible in real time via RS 485 & supports MODBUS protocol.

The BI 9100 AQMS Air Quality Station meets the global trend for real time measurement of air quality in the micro-environment.

Portable Ambient Air Quality Monitoring Analyzer BI 9100
  • 7 Inch Touch Screen Display
  • 32 Bit powerful ARM processor
  • Remote site operation
  • Negligible zero and span calibration slope drift
  • PC software included
  • Zero and Span calibration of gases at site
  • Built-in zero air scrubber
  • Excellent linearity and sensitivity
  • Real time data acquisition
  • MODBUS communication
  • Multiple gas measurements
  • Multi-point factory calibration
  • Active sampling via brushless pumps
  • Measurement up to 6 parameters under one roof
  • Lower capital cost for affordable profiling and assessments
  • Sensor Technology
  • Electrochemical,
    Non Dispersive Infrared Absorption (NDIR),
    PID,
    Light Scattering
  • Measurement Gas
    • O2
      :0-25%
    • CO
      :0-50 ppm
    • NO
      :0-5000 ppb
    • NO2
      :0-5000 ppb
    • SO2
      :0-5000 ppb
    • H2S
      :0-10000 ppb
    • O3
      :0-10000 ppb
    • NH3
      :0-25 ppm
    • Cl2
      :0-10000 ppb
    • CO2
      :0-2000 ppm
    • CH4
      :0-2000 ppm
    • TVOC
      :0-1000, 0-10000 ppm
    • HCl
      :0-10 ppm
    • PM10
      :0-1999 µg/m3
    • PM2.5
      :0-999 µg/m3
  • Operating Conditions
  • 0 to 50ºC Ambient Temperature
  • Power Requirements
  • 12 V/24V DC Adaptor
  • Computer Interface
  • RS 232, RS 485, supports MODBUS protocol
  • Relative Humidity Range
  • 15 to 85%
  • Pressure Range
  • Atmospheric ± 10%
  • Park and forest monitoring
  • Indoor air quality monitoring
  • Industrial perimeter air quality monitoring
  • Local community exposure: residential, schools, hospitals
  • Construction site monitoring
  • Urban air quality monitoring
  • Near road air quality monitoring
  • Ecological Mobility Management
  • Long term air quality trend analysis
  • Environmental Impact Assessments
  • Low cost air quality networks to support reference AAQM stations