Continuous Emission Monitoring System
Agasthya 2013 Series
BI 7000 NDUV – CPCB Compliance

The Agasthya 2013 Series Continuous Emission Monitoring System BI 7000 (NDUV) is designed
in compliance to emission norms to measure gaseous pollutants emitted by various process industries,
offering a cost effective and reliable multi-gas analyzer solution.

BI 7000 (NDUV) is TUV certified for CE mark & Performance as per EN15267 standard.

The system employs Non-Dispersive Ultraviolet (NDUV) technology, providing high reliability
and accuracy to ensure superior performance and long operational life.

With a modular design, the BI 7000 (NDUV) adapts to diverse process applications, supports up to eight gas
sensors with scalable ranges, and is housed in a robust industrial enclosure suitable for hostile and
friendly environments.

Continuous Emission Monitoring System - BI 7000 NDUV
  • Tried and tested technology with proven reliability
  • Scalable ranges available for each gas
  • 5.6” Smart Touchscreen Display
  • The best price performance on the market – designed with user requirements foremost in mind
  • Isolated 4-20 mA analog output for each gas
  • RS 485, MODBUS protocol
  • High / Low Gas, low flow & other programmable events available
  • Highly efficient automatic purge & drain system
  • Inbuilt interface for Remote Calibration Unit
  • Auto & semi auto calibration facilities

Analyzer Specification

  • Sensor Technology
    • Non Dispersive Ultraviolet Absorption (NDUV)
  • Measurement Gas
    • NO2
      : 0-1000 ppm scalable
    • SO2
      : 0-1000 ppm scalable
    • Cl2
      : 0-30 ppm scalable
    • H2S
      : 0-50 ppm scalable
  • Resolution
  • 0.10% (HC, CO2, O2)
    1 ppm (Other Gases)
  • Accuracy
  • ±1% FSD
  • Repeatability
  • 1% FS
  • Zero Drift
  • <±1% per week of Span
  • Span Drift
  • <±1% per week of Span
  • Analog Output
  • 4-20mA analog output
  • Response
  • T90 < 200 sec
  • Digital Interface
  • RS 485, MODBUS Protocol
  • Relay Output
  • 2 Nos. relay for alarms
  • Power Supply
  • 110/230 VAC, 50 Hz
  • Dimension
  • 19” Rack

CEMS Specification

Heated Sampling Probe

  • Operating temperature
    : Max. 400ºC
  • Mounting
    : Flange type. 2”, 150# rating RF
  • Max. working pressure
    : 6 bar
  • Voltage
    : 110-230 V, 50 /60 Hz
  • Heating
    : Self-regulating +180ºC
  • For dust concentration
    : Upto 5 g/m³
  • MOC
    : SS 316

Heated Sample Gas Line

  • Process Tube
    : PTFE / SS
  • Process Tube Size
    : 1/4 inch OD
  • Operating Voltage
    : 230 V AC
  • Max. Operating Temperature
    : 200ºC

Sample Conditioning Unit with Industrial Cabinet

  • Aspirator/Pump for sampling flue gas
  • Pre and post cooler fine filters to remove drain, dust and mist in sample gas
  • Auto drain and auto purging (blow back) facilities
  • 2 way solenoid valves for switching, sampling, purging, draining and calibration
  • Flowmeter to regulate and monitor the flow of sample gas
  • Drain pump for continuous removal of condensate
  • Sample Gas Cooler
  • Industrial Cabinet Dimension: 1500 (H) x 600 (W) x 800 (D) mm
  • Aluminium
  • Cement
  • Distillery
  • Chlor Alkali
  • Fertilizers
  • Iron & steel
  • Oil refinery
  • Petrochemical
  • Pharmaceuticals
  • Power Plants
  • Thermal Power Plants
  • Pulp & paper
  • Sugar
  • Zinc
  • Copper
  • Boiler
  • Biomedical waste Incinerator
  • Common Hazardous Waste Incinerator

    Related Products